To Speak to a U.S. Based Lighting Pro
1-800-624-4488

Fluorescent Emergency Ballasts, Battery Backups

 
Iota I32 TBTS - Reduced Profile Emergency Backup Ballast - 90 min. - Operates Most 2 ft. - 4 ft. single, Bi-Pin, T8 through T12 and 28W T5 Lamps - 120/277 Volt


IOTA-10006

Iota logo (3)
Iota I32 TBTS - Emergency Backup Ballast
Reduced Profile 90 min. - Operates Most 2 ft. - 4 ft. single, Bi-Pin, T8 through T12 and 28W T5 Lamps
  • Voltage: 120, 277
  • Max. Light Output: 500 Lumens
  • Operates: F28T5
  • Length: 9.5 in.

  • Height: 1 in.
  • Width: 2 in.
  • Warranty: 5-Year Limited
Attribute Image 0
Emergency Backup Ballast - 90 min. - Operates (1-2) T5, T8, T10, T12, LED Retrofits - 120-277 Volt Exitronix XEB2-14-LM


EX-XEB214LM

Exitronix logo (1)
Emergency Backup Ballast - 90 min.
Operates (1-2) T5, T8, T10, T12, LED Retrofits - 120/277 Volt - Exitronix XEB2-14-LM
  • Family: XEB-14 Series
  • Voltage: 120, 277
  • Ratings and Certifications: Indoor, UL
  • Emergency Operation: 90 Minutes
  • Lamps Operated: (1) or (2) Lamps
  • Max. Light Output: 1,400 Lumens

  • Operates: (1) or (2) Linear Tube or CFL
  • Length: 13.3 in.
  • Height: 1.5 in.
  • Width: 2.4 in.
  • Weight: 3.4 lbs.
  • Warranty: 5-Year Limited
Attribute Image 0Attribute Image 1
Exitronix XEB-75-CF-LM - Emergency Backup Ballast - 90 min. - Operates (1) 13 to 42 Watt or (2) 13 to 18 Watt 4-Pin Lamps - 120/277 Volt


EX-XEB75CFLM

Exitronix logo (1)
Exitronix XEB-75-CF-LM - Emergency Backup Ballast
90 min. - Operates (1) 13 to 42 Watt or (2) 13 to 18 Watt 4-Pin Lamps - 120/277 Volt
  • Family: XEB-75-CF-B-LM Series
  • Voltage: 120
  • Ratings and Certifications: Indoor, UL
  • Emergency Operation: 90 Minutes
  • Lamps Operated: (1) or (2) Lamps
  • Max. Light Output: 750 Lumens

  • Operates: (1) or (2) 4-Pin CFLs
  • Length: 9.4 in.
  • Height: 1.5 in.
  • Width: 2.4 in.
  • Weight: 2.1 lb.
  • Warranty: 5-Year Limited
Attribute Image 0
Lithonia Lighting PS600QD - Emergency Backup Battery - 90 min. - Operates (1-2) 16 to 40 Watt - 2 ft. to 4 ft. T5, T8, or T12 - 120/277 Volt


LITH-0101

Lithonia Lighting logo
Lithonia Lighting PS600QD - Emergency Backup Battery
90 min. - Operates (1-2) 16 to 40 Watt - 2 ft. to 4 ft. T5, T8, or T12 - 120/277 Volt
  • Voltage: 120
  • Ratings and Certifications: Indoor, UL
  • Emergency Operation: 90 Minutes
  • Max. Light Output: 600 Lumens
  • Start Temp. (Min): 32 Deg. F
  • Start Temp. (Max): 100 Deg. F

  • Length: 9.04 in.
  • Height: 1.2 in.
  • Width: 2.2 in.
  • Weight: 2 lbs.
  • Warranty: 5-Year Limited
Attribute Image 0
Bodine B30ST - Emergency Backup Battery - 90 Min. - Operates Most 2 ft. to 8 ft. Single, Bi-Pin, T5, T8, T9, T10, T12 Lamps - 120/277 Volt


B-B30ST

Bodine logo (0)
Bodine B30ST - Emergency Backup Battery
90 Minutes - Operates most 2 ft. to 8 ft. Single, Bi-Pin, T5, T8, T9, T10, T12 Lamps - 120/277 Volt
  • Voltage: 120
  • Emergency Operation: 90 Minutes
  • Max. Light Output: 1800-3500 Lumens
  • Length: 16.6 in.

  • Height: 2.85 in.
  • Width: 2.8 in.
  • Weight: 7.5 lb.
  • Warranty: 5-Year Limited
Attribute Image 0
Emergency Backup Battery - 90 Min. - Operates Most 2 ft. to 8 ft. Single, Bi-Pin, T8, T9, T10, T12 Lamps - 120/277 Volt - Bodine B50ST


B-B50ST

Bodine logo (1)
Bodine B50ST - Emergency Backup Battery
90 Minutes - Operates most 2 ft. to 8 ft. Single, Bi-Pin, T8, T9, T10, T12 Lamps - 120/277 Volt
  • Voltage: 120
  • Emergency Operation: 90 Minutes
  • Max. Light Output: 1,400 Lumens
  • Length: 13.3 in.

  • Height: 1.5 in.
  • Width: 2.4 in.
  • Weight: 3.6 lb.
  • Warranty: 5-Year Limited
Attribute Image 0

Fluorescent Emergency Ballasts

When emergency situations arise and the main power grid is offline, don't sit in the dark. At 1000Bulbs.com, our selection of fluorescent emergency ballasts can provide power to a wide assortment of fluorescent lamps. We have emergency ballasts for T5 linear fluorescent tubes, T8 and T12 linear tubes, as well as compact fluorescent lighting. Give us a call and let our friendly customer service representatives help you to prepare for any lighting failure.