T5 LED Tube Lights - Fluorescent Tube Replacements
- FILTERS:
- Color Temperature : 5000 Kelvin
- RESET
2 ft. LED T5 Tube - 5000 Kelvin - 1400 Lumens - Type A Plug and Play - Operates with Compatible T5 Ballast
F24T5/HO Replacement - 11 Watt - 120-177 Volt - Case of 25 - PLT-50320
- Wattage: 11 Watt
- Compatibility: Program Start
- Fluorescent Equal: 24 Watt
- Operation: Type A Plug and Play
- Lampholder(s): Non-shunted
- Length: 22.17 in.
2 ft. LED T5 Tube - 5000 Kelvin - 1500 Lumens - Type A/B Hybrid - Operates With or Without Ballast
F24T5/HO Replacement - 12 Watt - Single-Ended or Double-Ended Powers - 120-277 Volt - Case of 25 - PLT-60034
- Wattage: 12 Watt
- Compatibility: Program Start, Rapid Start
- Fluorescent Equal: 24 Watt
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type A/B Hybrid
- Lampholder(s): Non-shunted, Shunted
- Length: 21.61 in.
4 ft. LED T5 Tube - 5000 Kelvin - 1800 Lumens - Type B - Operates Without Ballast
F28T5 Replacement - 12.5 Watt - Single-Ended Power or Double-Ended Power - 120-277 Volt - Case of 25 - PLT-90371
- Wattage: 12.5 Watt
- Fluorescent Equal: 28 Watt
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
- Length: 45.8 in.
1800 Lumens - 12 Watt - 5000 Kelvin - 4 ft. LED T5 Tube - Type C
F28T5 Replacement - Required External Driver Sold Separately - 120-277 Volt - Case of 25 - TCP LT5HE13C50K
- Compatibility: Instant Start, Program Start
- Operation: Type C External Driver
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T5 Tube - Color Selectable - 1800 Lumens - Type B - Operates Without Ballast
F28T5 Replacement - 12.5 Watt - Kelvin 3000-3500-4000-5000-6500 - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLT-50316
- Wattage: 12.5 Watt
- Fluorescent Equal: 28 Watt
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
- Length: 45.8 in.
3 ft. LED T5 Tube - 5000 Kelvin - 2250 Lumens - Type A/B Hybrid - Operates With or Without Ballast
F39T5/HO - 18 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLT-60037
- Wattage: 18 Watt
- Coating: PET
- Compatibility: Program Start, Rapid Start
- Fluorescent Equal: 39 Watt
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type A/B Hybrid
- Lampholder(s): Non-shunted, Shunted
- Length: 35.2 in.
4 ft. LED T5 Tube - Color Selectable - 3500 Lumens - Type B - Operates Without Ballast
F54T5/HO Replacement - 25 Watt - Kelvin 3000-3500-4000-5000-6500 - Single-Ended Power or Double-Ended Power - 120-277 Volt - Case of 25 - PLT-50317
- Color Temperature: 3000 Kelvin, 3500 Kelvin, 4000 Kelvin, 5000 Kelvin, 6500 Kelvin, Selectable CCT
- Wattage: 25 Watt
- Fluorescent Equal: 54 Watt
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
- Length: 45.8 in.
1600 Lumens - 13 Watt - 5000 Kelvin - 4 ft. LED T5 Tube - Type B Ballast Bypass
F28T5 Replacement - Single-Ended Power - 120-277 Volt - Case of 25 - TCP LT5HE13B150K
- Wiring: Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted
4 ft. LED T5 Tube - 5000 Kelvin - 3500 Lumens - Type B - Operates Without Ballast
F54T5/HO Replacement - 25 Watt - Double-Ended Power - 120-277 Volt - Case of 25 - PLT - LEDT-10081
- Wattage: 25 Watt
- Fluorescent Equal: 54 Watt
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
- Length: 45.8 in.
- Case Quantity: 25
4 ft. LED T5 Tube - 5000 Kelvin - 3200 Lumens - Type A/B Hybrid - Operates With or Without Ballast
F54T5/HO Replacement - 24 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLTS-60021
- Wattage: 24 Watt
- Compatibility: Program Start, Rapid Start
- Fluorescent Equal: 54 Watt
- Operation: Type A/B Hybrid
- Lampholder(s): Non-shunted, Shunted
- Length: 45.8 in.
LED - 54T5 - High Output - 5000K - Type B Ballast Bypass - Replacement for F54T5/HO/5000K
Single-Ended Power - 120-277 Volt - Case of 25 - Halco 82988
- Wiring: Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted
4 ft. LED T5 Tube - Color Selectable - 3120 Lumens - Type B - Operates Without Ballast
F54T5/HO Replacement - 24 Watt - Kelvin 3500-4000-5000-6500 - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLT-60039
- Wattage: 24 Watt
- Fluorescent Equal: 54 Watt
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
- Length: 45.2 in.
LED - 54T5 - High Output - 5000K - Hybrid A+B - Replacement for F54T5/HO/5000K
Operates with Compatible T5 Ballast or as Ballast Bypass - 120-277 Volt - Case of 25 - Euri Lighting ET5-24W305H
- Wiring: Double-Ended Wiring
- Operation: Type A/B Hybrid
- Lampholder(s): Shunted
1700 Lumens - 12 Watt - 5000 Kelvin - 2 ft. LED T5 Tube - Type B Ballast Bypass
F24T5/HO Replacement - Double-Ended Power - 120-277 Volt - Case of 25 - LEDVANCE 41988
- Wiring: Double-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
1400 Lumens - 12 Watt - 5000 Kelvin - 2 ft. LED T5 Tube - Type B Ballast Bypass
F24T5/HO Replacement - Single-Ended Power - 120-277 Volt - TCP LT5HO12B150K
- Wiring: Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted
Made to effectively replace linear fluorescent tubes, T5 LED tubes are an energy efficient alternative for linear fixtures, strip lights, shop lights, and troffers. LED tube lights not only operate on a fraction of the wattage, but also perform up to 50,000 hours. These T5 LEDs come in Kelvin temperatures ranging from 3000 Kelvin to 5000 Kelvin.
T5 LED tubes are available for plug-and-play, ballast bypass, or hybrid operation. Plug-and-play tubes operate with compatible ballasts and are installed quickly by simply removing the existing fluorescent and plugging in the LED tube. These tubes work with electronic, programmed start, or instant start ballasts, but it is best practice to verify the type of fluorescent ballast your fixture has and if the LED tube is compatible.
Ballast bypass tubes, also known as direct wire tubes, do not require ballasts and operate directly off the fixture's line voltage. The ballast is removed during installation, greatly reducing maintenance costs, and the fixture rewired depending on the tube's operation. Single-ended tubes only require power on one end and non-shunted sockets, while double-ended tubes need to be powered on both ends and can be use with either shunted or non-shunted sockets.
Hybrid tubes offer a mix of plug-and-play and ballast bypass operation. These lamps can be initially installed as plug-and-play lamps, requiring a compatible ballast in order to operate. Once the ballast reaches the end of its life, the hybrid tubes can then be reinstalled as ballast bypass.
Not sure which ballast bypass, plug-and-play, or hybrid LED T5 tube is right for your fixtures? Call 1-800-624-4488 now to speak with one of our knowledgeable lighting experts!