Fluorescent Ballasts - Electronic & Magnetic
Advance Centium - 2 Lamp Ballast - ICN-2P32-N
(2) Lamp - F32T8 - 120/277 Volt - Instant Start - 0.89 Ballast Factor
- Family: Centium
- Wattage: 32 Watt
- Voltage: 120, 208, 240, 277
- Ratings and Certifications: CSA, UL Indoor
- Ballast Factor: 0.89
- NEMA: Premium
- Start Temp. (Min): 0 Deg. F
- Power Factor: 97%
- Start Method: Instant Start
- Type: Electronic Fluorescent
- Warranty: 3 to 5 Years Limited

Advance Optanium IOP-A2P32-LW-N
(2) Lamp - F32T8 - 120/277 Volt - Instant Start - 0.77 Ballast Factor
- Family: Optanium
- Wattage: 32 Watt
- Voltage: 120
- Ratings and Certifications: CSA, UL Indoor
- Ballast Factor: 0.77
- Start Temp. (Min): -20 Deg. F
- Power Factor: 99%
- Start Method: Instant Start
- Type: Electronic Fluorescent
- Warranty: 5-Year Limited
Advance SmartMate ICF-2S26-H1-LDK
Operates (1 or 2) 26 Watt (1) 32 Watt or (1) 42W 4 pin CFL 120/277 Volt Programmed Start
- Family: SmartMate
- Wattage: 26 Watt, 42 Watt
- Voltage: 120
- Ratings and Certifications: CSA, UL Indoor
- Ballast Factor: 1
- Start Temp. (Min): 0 Deg. F
- Power Factor: 98%
- Start Method: Programmed Start
- THD: 10%
- Length: 4.98 in.
- Height: 1 in.
- Width: 2.4 in.
- Weight: 0.65 lb.
- Warranty: 3 to 5 Years Limited

SYLVANIA Quicktronic 49853
(2) Lamp - F32T8 - 120/277 Volt - Instant Start - 0.88 Ballast Factor
- Family: Quicktronic
- Wattage: 32 Watt
- Voltage: 120
- Ratings and Certifications: CSA, UL Indoor
- Ballast Factor: 0.88
- NEMA: Premium
- Start Temp. (Min): -20 Deg. F
- Start Method: Instant Start
- Type: Electronic Fluorescent
- Warranty: 5-Year Limited

Advance Optanium IOPA-2P32-N
(2) Lamp - F32T8 - 120/277 Volt - Instant Start - 0.87 Ballast Factor
- Family: Optanium
- Wattage: 32 Watt
- Voltage: 120
- Ratings and Certifications: CSA, UL Indoor
- Ballast Factor: 0.87
- Start Temp. (Min): -20 Deg. F
- Power Factor: 99%
- Start Method: Instant Start
- Type: Electronic Fluorescent
- Warranty: 5-Year Limited
GE UltraMax L 72262
(2) Lamp - F32T8 - 120/277 Volt - Instant Start - 0.77 Ballast Factor
- Order Code: GE232MAX-L/ULTRA
- Family: UltraMax L
- Voltage: 120
- Ratings and Certifications: UL Indoor
- Ballast Factor: 0.77
- NEMA: Premium
- Start Temp. (Min): 0 Deg. F
- Power Factor: 99%
- Start Method: Instant Start
- Type: Electronic Fluorescent
- Warranty: 5-Year Limited
- Case Quantity: 10

Universal Triad B259IUNVHP-A
(2) Lamp - F96T8 - 120-277 Volt - Instant Start - 0.88 Ballast Factor
- Family: Triad
- Voltage: 120
- Ratings and Certifications: CSA, Title 20, UL Indoor/Outdoor
- Ballast Factor: 0.88
- Start Temp. (Min): 32 Deg. F
- Power Factor: 99%
- Start Method: Instant Start
- THD: 20%
- Length: 9.5 in.
- Height: 1.18 in.
- Width: 1.7 in.
- Weight: 1.7 lb.
- Warranty: 5-Year Limited
- Case Quantity: 10

Advance IOP-2P59-N - (2) Lamp - F96T8
120-277 Volt - Instant Start - 0.87 Ballast Factor
- Family: Optanium
- Voltage: 120
- Ratings and Certifications: CSA, UL Indoor
- Ballast Factor: 0.87
- Start Temp. (Min): 32 Deg. F
- Power Factor: 0.98
- Start Method: Instant Start
- THD: 10%
- Length: 9.5 in.
- Height: 1 in.
- Width: 1.3 in.
Universal Triad C2642UNV
(2) Lamp - 26 Watt CFL - 120/277 Volt - Programmed Rapid Start - 0.98 Ballast Factor
- Family: Triad
- Voltage: 120
- Ratings and Certifications: UL Indoor
- Ballast Factor: 0.98
- Start Temp. (Min): 0 Deg. F
- Power Factor: 98%
- Start Method: Rapid Start
- THD: 10%
- Length: 4.94 in.
- Height: 1 in.
- Width: 2.31 in.
- Weight: 0.57 lb.
- Warranty: 5-Year Limited

Sola E-725-U-224-R1-S - (2) Lamp - F24T5/HO - (1) Lamp - F39T5/HO
120/277 Volt - Programmed Start - 0.90 Ballast Factor
- Voltage: 120
- Ballast Factor: 0.9
- Power Factor: 98%
- Start Method: Programmed Start
- THD: 15%
- Warranty: 5-Year Limited

Advance Optanium IOP-2P32-LW-N
(2) Lamp - F32T8 - 120/277 Volt - Instant Start - 0.77 Ballast Factor
- Family: Optanium
- Voltage: 120
- Ratings and Certifications: CSA, UL Indoor
- Ballast Factor: 0.78
- Start Temp. (Min): -20 Deg. F
- Power Factor: 99%
- Start Method: Instant Start
- Type: Electronic Fluorescent
- Warranty: 5-Year Limited
Hatch HC226/PS/UV/K CFL Ballast
Smart Kit - (2) LAMP - 26 WATT CFL - 120/277 Volt - Programmed Start
- Voltage: 120
- Ballast Factor: Normal
- Start Method: Programmed Start
- THD: 10%
- Length: 4.32 in.
- Height: 1 in.
- Width: 2.4 in.
- Warranty: 5-Year Limited
Sola E-724-U-226-M1-S
(1-2) Lamps - 21 to 42 Watt CFL - 120/277 Volt - Programmed Start - 0.85 Ballast Factor
- Voltage: 120
- Ratings and Certifications: CSA, UL Indoor/Outdoor
- Ballast Factor: 0.85
- Power Factor: 98%
- Start Method: Programmed Start
- THD: 10%
- Warranty: 5-Year Limited
Fulham RaceHorse RHA-UNV-226-C
(2) Lamp - 26 Watt CFL - 120/277 Volt - Programmed Start - 1.06 Ballast Factor
- Family: Racehorse
- Maximum Wattage: 57 Watts
- Voltage: 120
- Amperage: 0.47 Amps
- Ballast Factor: 1.06
- Start Temp. (Min): -22 Deg. F
- Power Factor: 98%
- Start Method: Programmed Start
- THD: 10%
- Length: 5 in.
- Height: 1 in.
- Width: 2.4 in.
- Weight: 0.45 lb.
- Warranty: 3-Year Limited
- Case Quantity: 50
Fulham Racehorse RHA-UNV-226-K - Contractor Kit
(1 or 2) Lamps - With a Max Load of 57 Watts - 120/277 Volt
- Family: Racehorse
- Maximum Wattage: 57 Watts
- Voltage: 120
- Amperage: 0.47 Amps
- Ballast Factor: 1.06
- Start Temp. (Min): -22 Deg. F
- Power Factor: 98%
- Start Method: Programmed Start
- THD: 10%
- Length: 5 in.
- Height: 1 in.
- Width: 2.4 in.
- Weight: 0.45 lb.
- Warranty: 3-Year Limited
- Case Quantity: 20