For Expert Help Call 1-800-624-4488

Fluorescent Ballasts | Plug-In CFL Ballasts | 2-Pin

 
Sola FCF-7/9-TP - (1) Lamp - 7 or 9 Watt CFL - 120 Volt - Preheat Start - 1.07 Ballast Factor


BS-FCF79TP

Sola FCF-7/9-TP
(1) Lamp - 7 or 9 Watt CFL - 120 Volt - Preheat Start - 1.07 Ballast Factor
  • Safety Rating: UL Indoor
  • Wattage: 7 Watt, 9 Watt
  • Maximum Wattage: 9 Watt
  • Voltage: 120
  • Ballast Factor: 1
  • Start Temp. (Min): 0 Deg. F
  • Power Factor: 48%, 52%
  • Start Method: Preheat Start

  • THD: 12%, 8%
  • CSA Listed: Yes
  • Length: 2.38 in.
  • Height: 1.25 in.
  • Width: 1.36 in.
  • Weight: 0.4 lb.
  • Warranty: 3 Years
  • Case Quantity: 24
$3.57 ea.

BS-FCF79TP

Sola FCF-13-TP - (1) Lamp - 13 Watt CFL - 120 Volt - Preheat Start - 0.81 Ballast Factor


BS-FCF13TP

Sola FCF-13-TP
(1) Lamp - 13 Watt CFL - 120 Volt - Preheat Start - 0.81 Ballast Factor
  • UPC: 660077100838
  • Safety Rating: UL Indoor/Outdoor
  • Wattage: 13 Watt
  • Voltage: 120
  • Ballast Factor: 0.81
  • Start Temp. (Min): 32 Deg. F
  • Power Factor: 0.5
  • Start Method: Preheat Start

  • THD: 13%
  • CSA Listed: Yes
  • Length: 2.38 in.
  • Height: 1.25 in.
  • Width: 1.36 in.
  • Weight: 0.44 lbs.
  • Warranty: 3 Years
  • Case Quantity: 24
$3.57 ea.

BS-FCF13TP

Advance H-1Q26-TP-BLS - (1) Lamp - 26 Watt CFL - 120 Volt - Preheat Start - 0.83 Ballast Factor


BA-H1Q26TPBLS

Advance H-1Q26-TP-BLS
(1) Lamp - 26 Watt CFL - 120 Volt - Preheat Start - 0.83 Ballast Factor
  • Safety Rating: UL Indoor/Dry Location
  • Wattage: 26 Watt
  • Voltage: 120
  • Ballast Factor: 0.83
  • Start Temp. (Min): 50 Deg. F
  • Power Factor: 98%
  • Start Method: Preheat Start

  • THD: 20%
  • CSA Listed: Yes
  • Length: 6.5 in.
  • Height: 1.5 in.
  • Width: 2.38 in.
  • Weight: 2.35 lb.
  • Warranty: 2 Years
$34.24 ea.

BA-H1Q26TPBLS

Robertson 01527P - (2) Lamp - 13 Watt CFL - 277 Volt - Preheat Start - 1.0 Ballast Factor


BR-EF213WGX23

Robertson 01527P
(2) Lamp - 13 Watt CFL - 277 Volt - Preheat Start - 1 Ballast Factor
  • ANSI Code: C82.1
  • Safety Rating: UL Indoor/Outdoor
  • Wattage: 13 Watt
  • Voltage: 277
  • Ballast Factor: 1
  • Start Temp. (Min): 32 Deg. F
  • Start Temp. (Max): 194 Deg. F
  • Power Factor: 20%, 40%

  • Start Method: Preheat Start
  • Type: Magnetic Fluorescent
  • CSA Listed: Certified
  • Length: 3.25 in.
  • Height: 1.94 in.
  • Width: 1.5 in.
  • Weight: 1.03 lb.
$36.89 ea.

BR-EF213WGX23

Advance H-2Q26-TP-BLSM - (2) Lamp - 26 Watt CFL - 120 Volt - Preheat Start - 0.92 Ballast Factor


BA-H2Q26TPBLSM

Advance H2Q26TPBLSM
(2) Lamp - 26 Watt CFL - 120 Volt - Preheat Start - 0.92 Ballast Factor
  • Safety Rating: UL Indoor/Outdoor
  • Wattage: 26 Watt
  • Voltage: 120
  • Ballast Factor: 0.92
  • Start Temp. (Min): 50 Deg. F
  • Power Factor: 99%
  • Start Method: Preheat Start

  • Type: Magnetic
  • CSA Listed: Yes
  • Length: 8.5 in.
  • Height: 1.69 in.
  • Width: 2.31 in.
  • Weight: 3.5 lb.
  • Warranty: 2 Years
$40.71 ea.

BA-H2Q26TPBLSM

Advance VH-2Q26-TP-BLS - (2) Lamp - 26 Watt CFL - 277 Volt - Preheat Start - 0.94 Ballast Factor


BA-VH2Q26TPBLS

Advance VH-2Q26-TP-BLS
(2) Lamp - 26 Watt CFL - 277 Volt - Preheat Start - 0.94 Ballast Factor
  • Safety Rating: UL Indoor
  • Wattage: 26 Watt
  • Voltage: 277
  • Start Temp. (Min): 50 Deg. F

  • Power Factor: 100%
  • Start Method: Preheat Start
  • CSA Listed: Yes
  • Warranty: 2 Years
$45.16 ea.

BA-VH2Q26TPBLS

Advance H-2B13-TP-BLS-M - (2) Lamp - 13 Watt CFL - 120 Volt - Preheat Start - 1.02 Ballast Factor


BA-H2B13TPBLSM

Advance H-2B13-TP-BLS-M
(2) Lamp - 13 Watt CFL - 120 Volt - Preheat Start - 1.02 Ballast Factor
  • Safety Rating: UL Indoor/Dry Location
  • Wattage: 13 Watt
  • Voltage: 120
  • Ballast Factor: 1.02
  • Start Temp. (Min): 32 Deg. F
  • Power Factor: Normal
  • Start Method: Preheat Start

  • THD: 30%
  • Type: Magnetic Fluorescent
  • CSA Listed: Yes
  • Length: 6.5 in.
  • Height: 1.5 in.
  • Width: 2.38 in.
$72.76 ea.

BA-H2B13TPBLSM

Compact Fluorescent Ballasts - 2 Pin Plug-In

Fluorescent bulbs need the proper ballast in order to operate properly and safely. These ballasts are designed for use with 2-pin plug-in CFL lamps that operate on a wide range of wattages and base types. These ballasts can be used in commercial settings such as offices, conference rooms or retail settings to operate singular or multiple CFL lamps. If you need any assistance finding the right ballast for your fixtures, contact us at 1-800-624-4488 to speak to one of our lighting experts.