To Speak to a U.S. Based Lighting Pro
1-800-624-4488

Fluorescent Ballasts - Electronic & Magnetic

 
Sola E-725-U-224-R1-S - (2) Lamp - F24T5/HO - (1) Lamp - F39T5/HO - 120/277 Volt - Programmed Start - 0.90 Ballast Factor


BS-E725U224R1S

Sola logo (2)
Sola E-725-U-224-R1-S - (2) Lamp - F24T5/HO - (1) Lamp - F39T5/HO
120/277 Volt - Programmed Start - 0.90 Ballast Factor
  • Voltage: 120
  • Ballast Factor: 0.9
  • Power Factor: 98%

  • Start Method: Programmed Start
  • THD: 15%
  • Warranty: 5-Year Limited
Attribute Image 0
Plusrite 7318 - (2) Lamp - F54T5/HO - 120/277 Volt - Programmed Start - 1.00 Ballast Factor


PLUSRITE-7318

Plusrite logo (13)
Plusrite 7318
(2) Lamp - F54T5/HO - 120/277 Volt - Programmed Start - 1.00 Ballast Factor
  • Order Code: BAF254PS/MV
  • Voltage: 120
  • Ratings and Certifications: Indoor, Outdoor, UL
  • Ballast Factor: 1

  • Start Method: Programmed Start
  • Warranty: 5-Year Limited
  • Case Quantity: 10
Attribute Image 0
Sola E-724-U-226-M1-S - (1-2) Lamps - 21 to 42 Watt CFL - 120/277 Volt - Programmed Start - 0.85 Ballast Factor


BS-E724U226M1S

Sola logo (2)
Sola E-724-U-226-M1-S
(1-2) Lamps - 21 to 42 Watt CFL - 120/277 Volt - Programmed Start - 0.85 Ballast Factor
  • Voltage: 120
  • Ratings and Certifications: CSA, Indoor, Outdoor, UL
  • Ballast Factor: 0.85
  • Power Factor: 98%

  • Start Method: Programmed Start
  • THD: 10%
  • Warranty: 5-Year Limited
Attribute Image 0
Sola E-725-U-228-R1-S - (2) Lamp - F28T5 - 120/277 Volt - Programmed Start - 0.88 Ballast Factor


BS-E725U228R1S

Sola logo (1)
Sola E-725-U-228-R1-S
(2) Lamp - F28T5 - 120/277 Volt - Programmed Start - 0.88 Ballast Factor
  • Voltage: 120
  • Ratings and Certifications: CSA, Indoor, UL
  • Ballast Factor: 0.88
  • Start Temp. (Min): 32 Deg. F
  • Power Factor: 98%
  • Start Method: Programmed Start

  • THD: 10%
  • Length: 16.5 in.
  • Height: 1.13 in.
  • Width: 1.19 in.
  • Weight: 0.95 lb.
  • Warranty: 5-Year Limited
Attribute Image 0
Sola E-725-U-239-R1-S - (1-2) Lamp - F39T5 - 120/277 Volt - Programmed Start - 0.90 Ballast Factor


BS-E725U239R1S

Sola logo (0)
Sola E-725-U-239-R1-S
(1-2) Lamp - F39T5 - 120/277 Volt - Programmed Start - 0.90 Ballast Factor
  • Voltage: 120
  • Ballast Factor: 0.9
  • Start Temp. (Min): 32 Deg. F
  • Power Factor: 98%
  • Start Method: Programmed Start
  • THD: 15%

  • Length: 17 in.
  • Height: 1.2 in.
  • Width: 2 in.
  • Weight: 1.25 lb.
  • Warranty: 5-Year Limited
Attribute Image 0
Plusrite 7319 - (4) Lamp - F54T5/HO - 120/277 Volt - Programmed Start - 1.00 Ballast Factor


PLUSRITE-7319

Plusrite logo (15)
Plusrite 7319
(4) Lamp - F54T5/HO - 120/277 Volt - Programmed Start - 1.00 Ballast Factor
  • Order Code: BAF454PS/MV
  • Voltage: 120
  • Ratings and Certifications: Indoor, Outdoor, UL
  • Ballast Factor: 1

  • Start Method: Programmed Start
  • Warranty: 5-Year Limited
  • Case Quantity: 10
Attribute Image 0

Fluorescent Ballasts at 1000Bulbs.com