Type B - Ballast Bypass - 4000 Kelvin - T8 Retrofit LED Tubes
4 ft. LED T8 Tube - 4000 Kelvin - 1800 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 15 Watt - Single-Ended Power - 120-277 Volt - Case of 25 - PLT-90031
- Wiring: Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted
4 ft. LED T8 Tube - 4000 Kelvin - 2200 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLTS-20110
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - 4000 Kelvin - 1900 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 12 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - Euri Lighting ET8-4040T-12
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - 4000 Kelvin - 1800 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLTS-20113
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - 4100 Kelvin - 2400 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 18.5 Watt - Single-Ended Power - 120-277 Volt - Case of 25 - TCP 88LT800003
- Wiring: Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted
4 ft. LED T8 Tube - 4000 Kelvin - 2200 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 15 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - Euri Lighting ET8-4040T-15
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - Color Selectable - 2200 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 17 Watt - Kelvin 3000-3500-4000-5000-6500 - 120-277 Volt - Case of 25 - PLT-50305
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - Color Selectable - 1800 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 14 Watt - Kelvin 3000-3500-4000-5000-6500 - 120-277 Volt - Case of 25 - PLT-50304
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - Wattage and Color Selectable - 2300 Lumen Max - Type B - Operates Without Ballast
F32T8 Replacement - Watts 12-15-18 - Kelvin 3000-3500-4000-5000-6500 - 120-277 Volt - Case of 25 - PLT-60040
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - 4000 Kelvin - 1800 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLTS-20120
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - 4000 Kelvin - 2200 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 14 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - Green Creative 37408
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - 5000 Kelvin - 1700 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 10 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - Green Creative 37405
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
High Lumen Output - 4 ft. LED T8 Tube - 4000 Kelvin - 3000 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 25 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - PLT-50334
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - 4100 Kelvin - 2370 Lumens - Type B - Operates without a Ballast
F32T8 Replacement - 18 Watt - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - Archipelago Lighting LT8F41841DE5
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
4 ft. LED T8 Tube - Color Selectable - 1700 Lumens - Type B - Operates Without Ballast
F32T8 Replacement - 10 Watt - Kelvin 3000-3500-4000-5000 - Single-Ended or Double-Ended Power - 120-277 Volt - Case of 25 - Green Creative 37229
- Wiring: Double-Ended Wiring, Single-Ended Wiring
- Operation: Type B Ballast Bypass
- Lampholder(s): Non-shunted, Shunted
Type B - Ballast Bypass - 4000 Kelvin - T8 Retrofit LED Tubes
Type B ballast bypass 4000 Kelvin T8 retrofit LED tubes are a type of energy-efficient lighting technology designed to replace traditional fluorescent lamps in commercial and residential settings. These LED tubes are characterized by their 4000 Kelvin color temperature, which produces a bright, neutral white light that is ideal for work environments and other settings where clear visibility is important.
The term "ballast bypass" refers to the fact that these LED tubes require the removal of the existing fluorescent ballast to operate. Instead, the LED tube is connected directly to the electrical circuit, typically using non-shunted lamp holders. This bypass process may require a licensed electrician to ensure proper installation and safety compliance.
By bypassing the ballast, these retrofit LED tubes can operate more efficiently, with lower energy consumption and longer lifetimes. They typically consume around half of the power used by traditional 32-Watt T8 fluorescent lamps, resulting in significant energy savings over time. Additionally, LED technology offers a far longer lifespan.